Close

SIMATIC LOGO!8

SIMATIC LOGO!8

LOGO! – small but wow

Even more versatile : The compact controller with a Cloud interface

LOGO! 8 The new generation of logic modules

LOGO! simple, simply, flexible, ingenious

With LOGO!, Siemens offers you the ideal controller for simple automation tasks in industry and building services. The modular design of LOGO! makes it consistently flexible. A wide range of modules allows you to create configurations to meet your needs.

Detail…

Highlights of the new LOGO! 8

  • 8 basic units for all voltages, four of them with a new display (3 colors changeable backlight : White, Orange and Red by user program)
  • All units come with an Ethernet interface and connections are compatible with previous versions (up to 8 network : CPU-CPU communication, Master-Slave, S7 Client-Server and Modbus TCP/IP Client-Server)
  • Several versions for different supply power DC 12V/24V RCE, AC/DC 24V RCE, DC 24V CE, AC/DC 115/240V RCE
  • 400 blocks program memory
  • Integrated web server in all basic units, additional with customized web pages with LOGO! Web Editor : a wizard guides you connecting to the Cloud, creating dashboard, control and analyze data (with our HTML programming knowledge)
  • Connectivity for remote LOGO! 8 text display via Ethernet for all LOGO! 8 basic modules
  • Extended temperature range -20 to 55°C, without condensation
  • I/O expandable up to 24 DI, 20 DO, 8 AI and 8AO


Even more versatile: The compact controller with a Cloud interface

LOGO! is compact, clever, and flexible, and now also comes with a direct line to the Cloud. It couldn’t be simpler. Enjoy an even wider range of potential applications and uses, with the same versatility and ease of programming.

siemens.com/logo

Versatile

The range of possible applications for LOGO! are more versatile than ever: With its new Cloud functionality it gives you access to the Internet of Things (IoT) and enables new business models like predictive maintenance and power data monitoring.

Easy and future-proof

A wizard guides you through the process of connecting LOGO! to the Cloud and creating dashboards using the LOGO! Web Editor (LWE) to control and analyze data. Getting started is a piece of cake thanks to intuitive engineering software, starter kits, and free web-based training sessions.

Expandable

With the new version of LOGO! you can expand existing applications to include Cloud functionality and move your web server to the Cloud, for example. You can network up to eight base modules with each other, or with SIMATIC controllers and HMI.


LOGO!8 with display

  • The space-saving basic variants
  • Interface for the connection of expansion modules, up to 24 digital inputs, 20 digital outputs, 8 analog inputs and 8 analog outputs can be addressed
  • All basic units with integrated web server
  • Enclosure width 72 mm (4 U)
  • All basic units with Ethernet interface for communication with
    LOGO! 8,  LOGO! TDE, SIMATIC Controllers, SIMATIC Panels and PCs
  • Use of standard micro CF cards

Detail…


LOGO!8 with display
LOGO! 24CE

6ED1052-1CC08-0BA1

  • Inputs of which can be used in analog mode: 4 (0 to 10 V)
  • Input/supply voltage: 24 V DC
  • Outputs: 4; transistors 
LOGO! 12/24RCE

6ED1052-1MD08-0BA1

  • Inputs of which can be used in analog mode:  4 (0 to 10 V)
  • Input/supply voltage: 12- 24 V DC 
  • Outputs:  4; relays 
LOGO! 24RCE

6ED1052-1HB08-0BA1

  • Inputs of which can be used in analog mode:    – 
  • Input/supply voltage: 24 V AC/DC
  • Outputs: 4; relays 
LOGO! 230RCE

6ED1052-1FB08-0BA1

  • Inputs of which can be used in analog mode:    – 
  • Input/supply voltage: 115-230V AC/DC
  • Outputs: 4; relays 

LOGO!8 Expansion modules

LOGO!8 without display

  • Relay outputs with max. 10 A output current.
  • Integrated EEPROM memory for control program and setpoint values.
  • Optional standard micro CF cards.
  • Integral real-time clock with automatic summer/winter time switchover.
  • Backup of the integrated real-time clock for 20 days.
  • 8 digital inputs, 4 digital outputs.
  • 4 inputs as analog inputs in 12/24 V DC variants (0 to 10 V); inputs can also be used digitally.
  • 4 inputs can be used for high-speed counting up to 5 kHz (DC versions only).
  • Interface for the connection of expansion modules, up to 24 digital inputs, 20 digital outputs, 8 analog inputs and 8 analog outputs can be addressed.
  • Connection of the LOGO! TDE text display to LOGO! 8 via Ethernet.

Detail…


LOGO!8 without display
LOGO! 24CEO

6ED1052-2CC08-0BA1

  • Inputs of which can be used in analog mode: 4 (0 to 10 V)
  • Input/supply voltage: 24 DC
  • Outputs: 4; transistors 
LOGO! 12/24RCEO

6ED1052-2MD08-0BA1

  • Inputs of which can be used in analog mode: 4 (0 to 10 V)
  • Input/supply voltage: 12 – 24 V DC
  • Outputs: 4; relays
LOGO! 24CEO

6ED1052-2CC08-0BA1

  • Inputs of which can be used in analog mode: 4 (0 to 10 V)
  • Input/supply voltage: 24 DC
  • Outputs: 4; transistors 
LOGO! 12/24RCEO

6ED1052-2MD08-0BA1

  • Inputs of which can be used in analog mode: 4 (0 to 10 V)
  • Input/supply voltage: 12 – 24 V DC
  • Outputs: 4; relays

Information

Digital I/O module… , Analog I/O module…

Brochure… , Product information… , Demo software…


Web based training

Introduction Videos

SIMATIC LOGO!8

Learning automation playfully with LOGO!

LOGO! goes Cloud – New Possibilities

LOGO! in operation for trout farming

LOGO! in operation for home automation

LOGO! goes cloud

Siemens AG – LOGO! Web Editor

LOGO! goes Cloud – LOGO! as Gateway

LOGO! automates the SPAs of the Starpool company

A mobile home for chicken


Quick start LOGO!

LOGO! Tips and Tricks – Light and fan control (EN)
LOGO! Tips and Tricks – Wiring (EN)
LOGO! downright simple to connect
LOGO! Tips and Tricks – 2 Line configuration (EN)
LOGO!8 Tips Video
01_First step LOGO!8

Quick start LOGO!8
LOGO! 101 Series
  • Basic programming EX02 : Function “OR” : Learn now…(no sound)
  • Basic programming EX03 : Function “Counter” : Learn now…(no sound)
  • Basic programming EX04 : Timer Functions “On-Off Delay” : Learn now…(no sound)
  • Basic programming EX05 : Timer functions “Yearly-Weekly Timer” : Learn now…(no sound)
  • Basic programming EX06 : Using Analog : Learn now…(no sound)
  • Basic programming EX07-1 : Using message texts Part 1 : Learn now…(no sound)
  • Basic programming EX07-2 : Using message texts Part 2 : Learn now…(no sound)
  • Basic programming EX08 : Change Display Color : Learn now…(no sound)
  • การใช้งาน Message Text : Learn now…
  • การเปลี่ยนสี Backlight : Learn now…
  • การใช้งาน On-Off Delay และ Network programming : Learn now…
  • การใชงาน Counter : Learn now…

LOGO!8 Tips and Tricks


LOGO! Tips and Tricks – Web editor (EN)

LOGO! goes Cloud – Cloud Connection with LOGO! Soft Comfort
LOGO! goes Cloud – Registration at Amazon Web Services and Setup
LOGO! Tips and Tricks – Monitoring values (EN)
LOGO! Tips and Tricks – Time as a bar graph (EN)
LOGO! Tips and Tricks – Marking connecting lines (EN)

LOGO! Tips and Tricks – Network project (EN)

LOGO! goes Cloud – Cloud Connection with LOGO! Web Editor
LOGO! Tips and Tricks – Digital bar graph (EN)
LOGO! Tips and Tricks – Configuring the startup time (EN)
LOGO! Tips and Tricks – Values in the trend view (EN)

Web based training


Thank you very much for your interested